FREE SHIPPING ON ORDERS OVER $70
Previous
Borosilicate glass microfiber Filters 42.5mm 1.5µm BIOSupplyHouse-0

Borosilicate glass microfiber Filters 42.5mm 1.5µm BIOSupplyHouse

Original price was: $73.00.Current price is: $70.08.
Next

Whatman 1825-047 Glass Microfiber Filter 0.7µm GF/F 4.7cm Diameter

Original price was: $170.96.Current price is: $94.68.
Whatman 1825-047 Glass Microfiber Filter 0.7µm GF/F 4.7cm Diameter-0

Whatman 1827-082 Glass Microfiber Binder Free Filter, 1.5 Micron,

Original price was: $99.41.Current price is: $94.44.

The Whatman 1827 082 glass microfiber filter provides reliable 1.5 micron particle retention while maintaining a rapid 3.7 seconds per 100 mL flow rate, making it ideal for high-throughput laboratory applications. Its borosilicate glass microfibre construction tolerates temperatures up to 500 C and offers high loading capacity, suitable for water pollution monitoring, cell harvesting, liquid scintillation counting, and air quality analysis.

9999 in stock
SKU: CJFCL6B00394 Category:
Trust Badge Image

Description

Product Overview

The Whatman 1827 082 glass microfiber filter is engineered for demanding laboratory environments where precision, speed, and durability are essential. Constructed from high‑purity borosilicate glass microfibres, the filter provides a smooth, binder‑free surface that captures particles down to 1.5 µm with exceptional efficiency. Its 8.2 cm diameter and Grade 934‑AH composition deliver a flow rate of 3.7 seconds per 100 mL, allowing rapid processing of large sample volumes without sacrificing retention quality. The filter’s robust glass matrix endures temperatures exceeding 500 °C, making it suitable for high‑temperature applications and repeated autoclaving. Certified to Standard Methods 2540D, it meets stringent criteria for total suspended solids analysis, turbidity removal, and bacterial culture filtration. The pack of 100 units ensures consistent performance across multiple experiments, reducing variability and supporting reproducible results.

[Product front view showing all components]

Usage

Designed for a broad spectrum of laboratory tasks, this filter excels in water pollution monitoring, where accurate detection of suspended solids is critical for environmental compliance. Researchers harvesting cells for downstream analysis benefit from the filter’s high loading capacity, which captures dense cell suspensions while maintaining gentle flow to preserve cell integrity. In liquid scintillation counting, the filter removes particulate interference, enhancing counting efficiency and reducing background noise. Air pollution monitoring labs also employ the filter to trap aerosolized contaminants before analysis. Its temperature resistance enables use in protocols requiring heat treatment, such as sterilization steps or high‑temperature extractions. The filter’s compatibility with standard laboratory filtration apparatus ensures seamless integration into existing workflows, minimizing the need for additional equipment.

Why Choose Us

Choosing the Whatman 1827 082 filter means selecting a product backed by decades of expertise in filtration technology. Whatman’s reputation for quality control guarantees each filter meets rigorous performance standards, delivering consistent retention and flow characteristics batch after batch. The binder‑free glass microfibre design eliminates potential leaching of organic binders, preserving sample purity—a critical factor for sensitive analytical methods. Our filters are manufactured under ISO‑9001 certified conditions, and each lot undergoes comprehensive testing for particle retention, flow rate, and thermal stability. In addition to product reliability, we provide responsive technical support, offering guidance on optimal filtration setups, troubleshooting, and method development. Our commitment to sustainability includes recyclable packaging and a focus on long‑lasting filter performance, reducing waste and operational costs for laboratories worldwide.

Key Features

  • Precise 1.5 µm particle retention ensures accurate analysis of fine particulates.
  • Rapid 3.7 seconds per 100 mL flow rate accelerates sample processing without compromising quality.
  • Binder‑free glass microfibre surface prevents contamination and maintains sample integrity.
  • Heat resistance up to 500 °C allows use in high‑temperature protocols and repeated autoclaving.
  • Dedicated technical support provides expert assistance for method optimization and troubleshooting.

FAQ

What types of samples can I filter with the 1827‑082?

The filter is suitable for aqueous solutions, cell suspensions, liquid scintillation cocktails, and aerosol samples collected for air quality analysis. Its high loading capacity and temperature tolerance make it versatile for both low‑temperature and high‑temperature applications.

Can the filter be reused after cleaning?

While the filter is designed for single‑use to guarantee maximum retention performance, it can be cleaned and re‑sterilized for non‑critical applications. However, reuse may reduce its retention efficiency, so for quantitative analyses a fresh filter is recommended.

Is the filter compatible with standard vacuum filtration apparatus?

Yes, the 8.2 cm diameter matches common laboratory filter holders and vacuum manifolds. It fits seamlessly into standard glass or plastic filtration setups, eliminating the need for adapter equipment.

How does the filter perform in high‑temperature sterilization?

The borosilicate glass microfibre construction withstands temperatures above 500 °C, allowing autoclaving at typical sterilization conditions (121 °C, 15 psi) without degradation of the filter matrix or loss of retention capability.

What quality certifications does the filter have?

The product complies with Standard Methods 2540D for total suspended solids determination and meets ISO‑9001 quality management standards. Each batch is tested for flow rate, particle retention, and thermal stability to ensure consistent performance.

Reviews